vllm - 💡(How to fix) Fix [CI Failure]: mi250_4: Hyrbid SSM NixlConnector PD accuracy tests (4 GPUs) [2 comments, 1 participants]

Official PRs (…)
ON THIS PAGE

Recommended Tools

×6

Utilities matched from this issue’s tags and category — try them while you read without losing context.

GitHub issue graph ai analysis

Paste a GitHub issue URL. We fetch that issue, discover linked issues from bodies/comments/timeline, collect linked pull requests, and produce a structured English report.

The report is written in English Markdown for sharing and archival.

Helpful · Quick feedback

Loading…
GitHub stats
vllm-project/vllm#40207Fetched 2026-04-19 15:05:47
View on GitHub
Comments
2
Participants
1
Timeline
6
Reactions
0
Participants
Timeline (top)
added_to_project_v2 ×2commented ×2labeled ×1project_v2_item_status_changed ×1
RAW_BUFFERClick to expand / collapse

AMD nightly — failing test group

Group: mi250_4: Hyrbid SSM NixlConnector PD accuracy tests (4 GPUs)

Current streak start: 2026-03-31 First failure in 60d window: 2026-03-31 Last successful nightly:Break frequency (60d, pass↔fail flips): 0 Latest nightly date: 2026-04-18 Latest build(s): #7791

Hardware status in latest nightly

hardwarestatus
mi250_4fail

Auto-managed by sync_ready_tickets.py. Closed + moved to Done when this group passes on all AMD hardware.

Last sync: https://github.com/AndreasKaratzas/vllm-internal-project-dashboard/actions/runs/24602867596

extent analysis

TL;DR

Investigate the mi250_4 hardware status and the Hyrbid SSM NixlConnector PD accuracy tests to identify the cause of the failing test group.

Guidance

  • Review the test results and hardware status for mi250_4 to determine the specific cause of the failure.
  • Check the sync_ready_tickets.py script for any potential issues or errors that may be contributing to the failure.
  • Investigate the test history to see if there were any changes or updates made to the Hyrbid SSM NixlConnector PD accuracy tests around the time the failures started.
  • Verify that the mi250_4 hardware is properly configured and functioning correctly.

Notes

The issue lacks detailed information about the test failures, so further investigation is needed to determine the root cause.

Recommendation

Apply workaround: Investigate and address the specific cause of the failure, as the issue is likely related to the mi250_4 hardware or the Hyrbid SSM NixlConnector PD accuracy tests.

Vote matrix · Quick signals

Works
Did the solution work? Tap to confirm.
Easy Fix
Was it a quick fix?
Time Saver
Did it save you time?
Blocking
Was it severely blocking?
Common Issue
Are others likely hitting this too?
Flaky / Intermittent
Is it intermittent?
Verified / Reproducible
Can you reproduce it reliably?
Loading…

Still need to ship something?

×6

Another batch ranked right after the header list — different links, same matching logic.

Back to top recommendations

TRENDING